    • OTA升级接收固件重启

      log输出如图,每次接收的数据长度都不固定 未见报错就重启了
      0_1676346194390_00c9ef6e-77d0-4cb7-9c96-dcc3355f8d2f-image.png

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 都有加的

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @ayu 稳定重现这个问题,每次都是在打印两个freqchip这个位置

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 0_1666687644625_7e1886f6-0c0e-45a1-9820-f021985e28e4-image.png 还是不行

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 在FR8016HA Dongle上测试也存在这个问题

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 复位时,在boot启动过程中(freqchip 未打印完全)往串口发送大量数据,有几率造成芯片挂掉,需要重新上电或者硬件复位

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 ☹ OK了,谢谢

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @ayu 作为主从一体的情况下,从机连接6个情况下,再使用手机连接竟然会把已经连接的设备挤掉☹

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      @刘流鎏 想多连几个,咋处理咧 最少一主八从

      posted in FR801xH
      A
      ayu
    • RE: 多从机连接重启问题

      log未显示报错信息

      posted in FR801xH
      A
      ayu